Home/Storage

Storage without a plant room.

Three floor-standing LiFePO4 cabinets at 51.2 V. No rack, no dedicated room, no wall to carry 228 kg. Roll it in, wire it up, commission it.

Product range

One footprint family, three capacities.

The cabinet grows in floor area, not in height, so a 30 kWh unit still fits under a standard industrial ceiling. All three share the same BMS, the same communication protocol and the same commissioning procedure.

Cabinet specification

15 / 20 / 30 kWh
Parameter15 kWh20 kWh30 kWh
Nominal voltage51.2 V51.2 V51.2 V
Rated capacity300 Ah400 Ah600 Ah
End-of-charge voltage58.0 V58.0 V58.0 V
End-of-discharge voltage42.0 V42.0 V42.0 V
Max. charge current200 A200 A200 A
Max. discharge current200 A200 A200 A
CommunicationRS485 / CANRS485 / CANRS485 / CAN
Dimensions (mm)495×240×880510×293×970460×380×995
Weight115 kg147 kg228.7 kg
ChemistryLiFePO4LiFePO4LiFePO4

Cabinet dimensions are width × depth × height. Depth grows with capacity, so check the door swing and the cable bend radius against your actual room, not against the footprint on a drawing.

ChemistryLiFePO4
Nominal voltage51.2 V
Charge / discharge200 A / 200 A
CommunicationRS485 / CAN
Capacity range15–30 kWh
Form factorFloor standing
Heaviest unit228.7 kg
On moving the 30 kWh. At 228.7 kg it needs a pallet truck or four people and a clear path. Tell us the access route at quotation stage — we have seen a 30 kWh unit arrive at a site with a 780 mm door.

Where it goes

Four situations where a cabinet beats a rack.

Rack batteries are cheaper per kWh and better at scale. A cabinet wins where there is no room, no rack and nobody on site with a torque wrench.

01

Retail and small C&I

Peak shaving behind the meter where the electrical room is already full. One cabinet, one wall circuit.

02

PV self-consumption

Store the midday surplus instead of exporting it at a negative price. Pairs with our own modules on the same site.

03

Weak-grid backup

Where the outage is measured in hours, not seconds. 200 A discharge carries a real load, not just a router.

04

Telecom and remote sites

Delivered assembled. No on-site cell stacking, no busbar torquing, no specialist labour.

System thinking

We would rather size the system than sell a box.

A cabinet on its own is a component. What most projects actually need is a PV array, a storage unit and a controller that agree with each other — and a single party accountable when they do not.

  • 01

    Load profile first

    Send 30 days of interval data and we will size the cabinet against your actual peak, not against a rule of thumb.

  • 02

    Inverter compatibility

    RS485/CAN with selectable protocols. Tell us the inverter model before you order — protocol matching after delivery is expensive.

  • 03

    One interface

    When the array and the cabinet come from us, the warranty question has one answer instead of two.

Send us the load profile.

Peak demand, daily cycle, backup hours required, inverter model. We will come back with a cabinet size and an honest note if storage is the wrong answer for your tariff.