HJT cell · G12-0BB

26.5%+,
in mass production.

210.1 × 105.05 mm half-cut cells, busbar-free, on 110 µm wafers. A −0.24%/°C temperature coefficient and up to 95% bifaciality — supplied to module makers and OEM partners.

8 POWER BINS  ·  25.3–26.0%  ·  2240 CELLS PER BOX

G12-0BB heterojunction solar cell, busbar-free front side with fine grid fingers

Standing storage · 15 / 20 / 30 kWh

Storage that
stands on its own.

Floor-standing LiFePO4 cabinets at 51.2 V, with 200 A charge and discharge and RS485/CAN communication. Three capacities on one footprint family — from 115 kg to 228 kg, for sites without a plant room.

LIFEPO4  ·  51.2 V  ·  200 A  ·  RS485 / CAN

Standing storage cabinets — 15 / 20 / 30 kWh 15 kWh 20 kWh 30 kWh

BIPV facade · XSXN-04

The façade
becomes the array.

880 × 480 mm building-integrated panels at 88 W and 208 W/m². Colour, texture and transmittance made to the architect's specification — standard finishes in ink-blue and gilded gold.

20.83% MODULE EFFICIENCY  ·  1500 V SYSTEM  ·  UV STABLE

Three building-integrated photovoltaic facade panels in ink blue, gilded gold and brushed silver
26.5%+
Cell efficiency
mass production
208W/m²
Facade output
per square metre
30kWh
Storage cabinet
largest unit
−0.24%/°C
Temperature coefficient
of Pmax
01 / 03

Product lines

Three things we make.
One platform underneath.

Cells for module makers, modules for EPCs and distributors, and storage-integrated systems for sites that cannot rely on the grid. All built on the same G12-0BB heterojunction process.

01 / CELLS

G12-0BB HJT cells

26.0%+ mass-production efficiency on 210 mm wafers, cut to 52.5 mm strips. Busbar-free design, silver-coated copper paste, wafer thickness down to 100 µm.

02 / MODULES

Uranus Pro & Venus Pro

730–765 W utility modules and 530–565 W commercial modules. Dual-glass, anodised aluminium frame, 30-year linear power warranty.

03 / SYSTEMS

Storage-integrated systems

PV plus storage plus microgrid control, sized for industrial parks, weak-grid sites and off-grid loads. Delivered as a configured system, not a component list.

Why heterojunction

The temperature coefficient is where the yield actually lives.

A module datasheet is measured at 25 °C. A working array rarely is. In high-irradiance markets the cell junction runs 30–45 °C above ambient, and every hundredth of a percent per degree compounds across the whole array, every day, for 30 years.

  • 01

    −0.24%/°C on Pmax

    Measured on our G12-0BB cell platform. At 70 °C junction temperature this is roughly 11% output retained versus 25 °C, against a materially steeper curve for mainstream tunnel-oxide cells.

  • 02

    Bifaciality up to 95%

    Dual-glass construction with a transparent rear. On a reflective ground surface the rear side contributes real kWh — which is why we size our utility module around it.

  • 03

    1% first-year degradation

    Then 0.4%/yr linear to year 30. Lower thermal stress and a lower-temperature process are the two reasons the curve stays flat.

Temperature coefficient of Pmax

%/°C

Shorter bar means less power lost per degree of heat. At 75 °C cell temperature that gap is worth about 3 percentage points against TOPCon.

HJT — 35E
−0.24
TOPCon
−0.30
PERC
−0.35

HJT value from 35 Energy module data. TOPCon and PERC shown at typical published values for orientation only; actual figures vary by manufacturer, bill of materials and test laboratory. Power at temperature also depends on irradiance, wind speed and mounting.

Where it goes

Built for high irradiance and high heat.

Our module is a 2384 × 1303 mm utility-format panel. It is designed for ground-mount and large commercial roofs — not for residential retrofit, where the format and 38.4 kg weight work against installers.

Manufacturing

A single-purpose HJT line, not a multi-technology compromise.

Our Meishan facility runs heterojunction only. That focus is what lets us push wafer thickness, paste consumption and cell efficiency at the same time instead of trading one for another.

  • A

    100 µm wafers in mass production

    Thinner silicon means less material per watt and a lower embodied carbon figure — both increasingly requested in European tenders.

  • B

    0BB busbar-free metallisation

    Removing the busbars cuts silver paste consumption by roughly 30% while raising the active area available for generation.

  • C

    20% silver-coated copper paste

    Already scaled on the line, with pure-copper paste and indium-free rear targets in qualification.

  • D

    33.45% tandem cell in the lab

    Perovskite-on-HJT stacked cell, verified in-house. This is the next step, not a shipping product — treat it as a technology roadmap indicator.

Dual-glass module cross-section FRONT GLASS 2.0 ENCAPSULANT HJT CELL ENCAPSULANT REAR GLASS 2.0 FRAME BIFACIAL

DUAL-GLASS, FRAMED · NOT TO SCALE

Compliance

Documents before promises.

A PV module is a regulated product in every market we sell into. We keep certification packages per target market and release the actual documents — certificate numbers, issuing bodies, test reports, declarations — to qualified buyers rather than putting unverifiable badges on a web page.

IEC 61215 design qualification IEC 61730 safety CE marking RoHS · REACH ISO 9001 QMS 30-year linear warranty
Certification scope varies by product series and destination market. Confirm current status with our compliance team before specifying into a tender.

Send us the project.
We will send back a yield model.

Give us the site, the capacity and the grid-connection date. You get a module recommendation, an energy-yield estimate and a landed-cost indication — not a brochure.